Multiplexers and OADMs – Powerful passive optical networking

At Smartoptics, we offer everything to help you get more out of your fiber networks. Including multiplexers and optical add/drop multiplexers (OADMs). An optical multiplexer combines wavelength channels onto an optical transmission fiber. OADMs are used in WDM systems for multiplexing and routing fiber optic signals, selectively adding and dropping individual or sets of wavelength channels from a DWDM stream. Both give you more flexibility in terms of the volume of traffic and type of data you want to transmit.

CWDM MUX/DEMUXES

HIGH BAND (1470-1610NM)

  • HIGH BAND (1470-1610NM)
    8 ch. CWDM Mux/Demux, C47-C61, IL Link=3.2dB, 1310nm expansion port, LC
  • HIGH BAND (1470-1610NM)
    8 ch. CWDM Mux/Demux, C47-C61, IL Link=2.8dB, LC
  • (HIGH BAND 1470-1610NM)
    4 ch. CWDM Mux/Demux, C51-C57, IL Link=2.4dB, 1310nm expansion port, LC
  • HIGH BAND (1470-1610NM)
    4 ch. CWDM Mux/Demux, C51-C57, IL Link=2.0dB, LC

LOW BAND (1270-1430NM)

  • LOW BAND (1270-1430NM)
    8 ch. CWDM Mux/Demux, C29-C43, IL Link=2.8dB, LC
  • LOW BAND (1270-1430NM)
    4 ch. CWDM Mux/Demux, C27-C33, IL Link=2.0dB, LC

SINGLE FIBER

  • SINGLE FIBER
    9 ch. CWDM Mux/Demux, single fiber, C29,C33,C37,C41,C45,C49,C53,C57,C61 IL Link=5.3dB, LC
  • SINGLE FIBER
    9 ch. CWDM Mux/Demux, single fiber, C27,C31,C39,C35,C43,C47,C51,C55,C59, IL Link=5.3dB, LC
  • SINGLE FIBER
    8 ch. CWDM Mux/Demux, single fiber, C29,C33,C37,C41,C47,C51,C55,C59, IL Link=4.7dB, LC
  • SINGLE FIBER
    8 ch. CWDM Mux/Demux, single fiber, C31,C35,C39,C43,C49,C53,C57,C61, IL Link=4.7dB, LC
  • SINGLE FIBER
    4 ch. CWDM Mux/Demux, single fiber, C47,C51,C55,C59, IL Link=3.5dB, 1310nm expansion port,LC
  • SINGLE FIBER
    4 ch. CWDM Mux/Demux, single fiber, C49,C53,C57,C61, IL Link=3.5dB, 1310nm expansion port, LC
  • SINGLE FIBER
    4 ch. CWDM Mux/Demux, single fiber, C47,C51,C55,C59, IL Link=2.8dB, LC
  • SINGLE FIBER
    4 ch. CWDM Mux/Demux, single fiber, C49,C53,C57,C61, IL Link=2.8dB, LC

1310/1550 BANDSPLITTERS

  • 1310/1550 BANDSPLITTERS
    2 ch. Wideband WDM, Mux/Demux, 1310/1550, IL Link=1.5dB, LC
  • 1310/1550 BANDSPLITTERS
    2 ch. Wideband WDM, Mux/Demux, 1310/1550, 1260-1458nm & 1464-1618nm, IL Link=1.5dB, LC
  • 1310/1550 BANDSPLITTERS
    2 ch. Wideband WDM cable, 1310/1550, IL Link=0.8dB, 1310 TRX site, ruggedized
  • 1310/1550 BANDSPLITTERS
    2 ch. Wideband WDM cable, 1310/1550, IL Link=0.8dB, 1550 TRX site, ruggedized
CWDM OADMS

DUAL FIBER

DWDM MUX/DEMUXES

AMPLIFIED PASSIVE NETWORKING

  • AMPLIFIED PASSIVE NETWORKING
    M-4001
    1U amplifier for use in Passive DWDM networks

40 CHANNEL, 50GHZ

  • 40 CHANNEL, 50GHZ
    40 ch. DWDM Mux/Demux, 50GHz, D9210-D9600, IL Link=10dB, DWDM expansion port with 50GHz Interleaver, LC
  • 40 CHANNEL, 50GHZ
    40 ch. DWDM Mux/Demux, 50GHz, D9215-D9605, IL=8dB, LC

40/32/16 CHANNEL, 100GHZ

  • 40 CHANNEL
    40 ch. DWDM Mux/Demux, 100GHz, D921-D960, IL Link=12.2dB, mon port, LC
  • 40 CHANNEL, LOW LOSS
    40 ch. DWDM Mux/Demux, 100GHz, D921-D960, IL Link=7.5dB, LC
  • 32 CHANNEL
    32 ch. DWDM Mux/Demux, 100GHz, D921-D936 & D943-D958, IL Link=6.4dB, mon port, LC
  • 16 CHANNEL
    16 ch. DWDM Mux/Demux, 100GHz, D921-D936, IL Link=5.0dB, DWDM expansion port, mon port, LC, xxxyyy = 921936, 943958

8 CHANNEL, 100GHZ

  • 8 CHANNEL
    8 ch. DWDM Mux/Demux, 100GHz, D943-D958, IL Link=4.8dB, DWDM expansion port, mon port, LC, xxxyyy = 921928, 929936, 943950, 951958

DWDM OVER CWDM

  • 8+8 CHANNEL, 1550NM WINDOW
    8 ch. DWDM Mux/Demux, 100GHz, Dxxx-Dyyy SO ch. plan, IL Link=5.0, IL UPG=1.2dB, DWDM expansion port, LC
  • 8 CHANNEL, 1550NM WINDOW
    8 ch. DWDM Mux/Demux, 100GHz, D925-D932, IL Link=3.8dB, LC
  • 10 CHANNEL, 1530NM WINDOW
    10 ch. DWDM Mux/Demux, 100GHz,D951-D960, IL Link=4.4dB, LC
  • DWDM OVER CWDM
    DWDMoCWDM Mux/Demux, D921-D960 over 1530/1550nm CWDM, IL Link=2.5dB, LC
DWDM OADMS

DUAL FIBER

  • EAST OR WEST
    1 ch. DWDM OADM, 100GHz, East or West, Dxxx, IL A/D=1.2dB, IL BP=0.8dB, LC
  • EAST OR WEST
    2 ch. DWDM OADM, 100GHz, East or West, Dxxx-Dyyy, IL A/D=1.8dB, IL BP=1.2dB, LC
  • EAST OR WEST
    4 ch. DWDM OADM, 100GHz, East or West, Dxxx-Dyyy, IL A/D=2.8dB, IL BP=0.6dB, LC
  • EAST AND WEST
    1 ch. DWDM OADM, 100GHz, East and West, Dxxx, IL A/D=1.2dB, IL BP=1.2dB, LC
  • EAST AND WEST
    2 ch. DWDM OADM, 100GHz, East and West, Dxxx-Dyyy, IL A/D=1.8dB, IL BP=1.8dB, LC
  • EAST AND WEST
    4 ch. DWDM OADM, 100GHz, East and West, Dxxx-Dyyy, IL A/D=3.2dB, BP=1.2dB, LC
  • MID STAGE ACCESS
    1 ch. DWDM OADM, 100GHz, East and West, Dxxx, IL A/D=1.2dB, IL BP=0.8dB, LC, mid stage access
  • MID STAGE ACCESS
    2 ch. DWDM OADM, 100GHz, East and West, Dxxx-Dxxx, IL A/D=1.8dB, IL BP=1.2dB, LC, mid stage access
  • MID STAGE ACCESS
    4 ch. DWDM OADM, 100GHz, East and West, Dxxx-Dxxx, IL A/D=2.8dB, IL BP=0.6dB, LC, mid stage access
  • BOOSTER / PREAMP ACCESS
    4 ch. DWDM OADM, 100GHz, East and West, Dxxx-Dxxx, IL A/D=3.2dB, IL BP=1.2dB, LC, booster preamp client access

How can we help?

Please contact Alliance Integrated Technology for a demo and design consultation.  info@allianceitc.com | 877-629-3020.